Insight Air – Smart aeration optimization

The Carbon Factor shows when aeration is truly effective—data-driven, patented, and reliable.

Insight Air

Smart aeration optimization.

The Carbon Factor reveals when air is actually effective and lays the groundwork for safe, data-driven ventilation optimization.
10 %
aeration energy use
Real-time
process signal
Patented
Carbon Factor
EP 3 693 344 B1 · EU

The most powerful way to save energy often goes unnoticed

Aeration is the largest source of energy consumption at wastewater treatment plants and is usually controlled based on dissolved oxygen levels. However, DO only indicates what is in the water, not what the biological process consumes.

Security surcharges

Aeration is driven by safety margins, not actual demand.

Energy with no benefit

More air does not mean better cleaning performance.

Process hidden

The true state of biology remains unclear.

A New Language for Biology

The Carbon Factor converts exhaust gas data into clear process information: the ratio of carbon degradation to nitrification, calculated from the O₂ and CO₂ in the exhaust air.

Carbon removal or nitrification

You can see in real time which reaction is currently taking place in the air.

Oxygen utilization

How effectively the oxygen supplied is actually utilized.

Effect of additional air

Whether increased aeration actually makes a difference right now or just wastes electricity.

From the sensor to a safe ventilation decision

Four steps to integrate the Carbon Factor as a control variable into your existing control system.

01 Trade Shows
EmiCo lite
Real-time exhaust gas analysis with 30 measurements per hour through the installation of EmiCo lite.
02 Calculate
Carbon Factor
Patented calculation based on the IPC of the measuring unit: the ratio of carbon degradation to nitrification. The results are displayed in EmiCo Insight.
03 Understanding
Stability window
System-specific - where nitrification and carbon degradation are in balance.
04 Optimize
aeration
Air factor (0.7–1.0) as a multiplier applied to the existing air requirement, in increments of ±5% every 10 minutes.
It’s not just about measuring; it’s about understanding whether the air has an effect.

Insight Air is a monitoring tool, not a replacement

Insight Air modifies the existing control system solely by applying a multiplier (air_factor 0.70–1.00). The DO control, minimum air flow, and safety logic of the PLC remain unchanged. A reduction occurs only if all four conditions are met simultaneously.

CF in the stability window

Biology in balance, an intervention is certain.

O₂ exhaust air > Threshold value

Over-aeration in the exhaust air can be clearly measured.

NH₄ below the limit value

Nitrification under control. Effluent limits values secured.

Measurement data 
valid

Watchdog OK, no critical device alarm.

If there is a loss of communication, a sensor failure, an increase in NH₄, or the dissolved oxygen level falls below the minimum threshold, the Air Factor immediately drops to 1.0. No exceptions.

Measurement, analysis, and implementation without disrupting the system

Variolytics delivers the tools. Control remains with you.

What Variolytics offers

  • EmiCo lite Measurement Technology (O₂, CO₂)
    EmiCo Insight (Software)
  • Patented calculation of the carbon factor
  • Handover of the Air-Factor and the automation concept

What remains with the operator

  • Plug-and-play installation on the system
  • On-premises integration with the existing control system
  • Full control – open, compatible, transparent

We will only intervene when the data from your system allows us to do so

Phase 0: 1–2 weeks
Preparation
Install the measurement equipment, establish the Modbus connection, and test the watchdog and all fail-safe logic.
Phase 1: 4 weeks
Observation without intervention
The logic continuously evaluates the process without interfering. CF stability windows and thresholds are based on real operational plant data.
Phase 2: 6–8 weeks
Closed-loop control
A conservative start with a threshold value at a relatively high oxygen concentration in the exhaust air, followed by a reduction.

Reference Project: Municipal Wastewater Treatment Plant, Southern Germany, 2025

2.47–7.02

CF Stability Window

17.5% ABV

O₂ threshold for exhaust air

0.3 mg/L

NH₄ Limit Procedure

€47,000–€129,000

Estimated savings per year

Patented technology

The Carbon Factor calculation method is patented across Europe (Patent EP 3 693 344 B1, granted in July 2025). The patent protects the method for real-time aeration control based on O₂ and CO₂ analysis of the off-gas from aeration tank valid in 35 European countries, including Germany, Austria, Switzerland, France, and the United Kingdom.
The Carbon Factor method cannot be reproduced or commercialised without a license from Variolytics.

Get to know Insight Air

Please feel free to schedule a personal consultation.

Consultation appointment
Discuss your investment in detail
Schedule an initial consultation, and we’ll work together to determine whether and how Insight Air fits into your process and control system.

FAQ – Frequently Asked Questions About Insight Air

EmiCo Insight Air is our software for optimizing ventilation using exhaust air data. It uses the patented Carbon Factor—calculated from the O₂ and CO₂ levels in the exhaust air—and shows when ventilation is truly effective. Based on this, Insight Air applies a factor to your existing air requirements—within safe limits—so that you can ventilate according to biological needs rather than relying on blanket reserves.

The Carbon Factor is the ratio of carbon removal to nitrification, calculated from O₂ and CO₂ in the effluent from the activated sludge tank. It shows in real time which reaction is currently consuming the air, how efficiently the oxygen being supplied is being used, and whether adding more air actually helps or just wastes electricity. Dissolved oxygen indicates what is in the water—not what the biological process is consuming.

No. Insight Air is a supervisor, not a replacement. It simply applies a multiplicative factor—the Air Factor, ranging from 0.70 to 1.00—to your existing air requirements. The DO control, minimum air flow, and safety logic of your PLC remain unchanged. Variolytics provides the components and the automation concept; you retain control of your system.

Insight Air reduces the air flow only if four conditions are met simultaneously: the Carbon Factor is within the system-specific stability window, O₂ in the exhaust air is above the threshold value, NH₄ is below the limit value, and the measurement data are valid. In the event of a loss of communication, sensor failure, rising NH₄ levels, or the DO level falling below the minimum, the Air Factor immediately reverts to 1.0.

On average, about 10% of the ventilation energy. It can be more or less: The result always depends on the capabilities of your process control system. Insight Air reduces the air flow only when the Carbon Factor, O₂ in the exhaust air, NH₄, and the measurement data allow it—so savings do not come at the expense of cleaning performance.

Commissioning takes place in three phases. Phase 0 (1–2 weeks): Install measurement equipment, establish the Modbus connection, and test the watchdog and all fail-safe logic. Phase 1 (4 weeks): The logic performs calculations but does not intervene; stability windows and threshold values are determined based on your actual plant data. Phase 2 (6–8 weeks): The closed-loop control system starts conservatively and is then gradually fine-tuned.

Variolytics provides the EmiCo lite measurement technology (O₂, CO₂), the EmiCo Insight software, the patented calculation of the Carbon Factor, and the transfer of the Air Factor as part of the automation concept. You retain responsibility for the plug-and-play installation on the system, the on-site integration with your existing control system, and full control over your process—open, connectable, and transparent.

This can happen when the biological system doesn’t get enough air: nitrous oxide is produced in both over- and under-aeration conditions. N₂O is not a control parameter for Insight Air—the control system operates based on the O₂ and CO₂ signals from the exhaust air. Because EmiCo lite measures nitrous oxide in that same exhaust air, you can immediately see how your emissions respond when the air flow changes.

Yes. The method for calculating the Carbon Factor is patented in Europe (EP 3 693 344 B1, granted in July 2025). It protects the method for real-time control of aeration based on the analysis of O₂ and CO₂ in the effluent from the activated sludge tank. The patent is valid in 35 European countries, including Germany, Austria, Switzerland, France, and the United Kingdom.

No. For ventilation control, you need EmiCo lite and EmiCo Insight Air—without Insight Report or Insight Assistant. You can add these packages later if you’d also like an annual report in CO₂ equivalents or recommendations for reducing nitrous oxide. This way, you start with what your ventilation system needs and expand as your facility’s needs grow.