EmiCo. lite - Emission measurement for wastewater treatment plants

Fast entry into the monitoring of nitrous oxide and methane

Why real-time emission monitoring is crucial

Wastewater treatment plants emit considerable amounts of greenhouse gases - especially nitrous oxide (N₂O), which is over 260 times more harmful to the climate than CO₂, and methane (CH₄). These emissions occur particularly when biological purification is not working optimally. With increasing legal requirements, it is becoming essential for operators to make these emissions visible and create regulatory certainty.

Precise real-time emission monitoring makes it possible not only to record emissions, but also to understand their causes. This is the only way to optimize processes, reduce costs and achieve sustainability goals.

EmiCo. lite was developed for this purpose: a fast, cost-efficient introduction to emissions monitoring - reliable, practical and ready for immediate use.

EmiCo. lite is a compact real-time measuring system for monitoring nitrous oxide (N₂O) and methane (CH₄) in the biological purification process. With two measuring points and a direct cloud connection, it enables operators to record emissions efficiently and optimize processes sustainably.

The system is plug & play and ready for operation within two hours - without complex installation or special tools. For wastewater facilities, this means: quick start, low investment, immediate results.

EmiCo. lite is based on non-dispersive infrared spectroscopy (NDIR). This proven measurement technology enables precise monitoring of greenhouse gases in the gas phase.

Measurable parameters:
Gas phase (vol. %): Nitrous oxide (N₂O), methane (CH₄), carbon dioxide (CO₂), oxygen (O₂, via integrated sensor)

In addition, flow and temperature measurements record the necessary context data so that concentrations are automatically converted into reliable emission rates. Detection limits of up to 2 ppm are achieved for nitrous oxide - precise enough to make even low emissions reliably visible.

EmiCo Insight makes measurement results immediately usable:

  • Interactive diagrams and intuitive dashboards provide a real-time overview
  • The EmiCo. Assistant automatically recognizes inefficient process states
  • Recommendations for action support operators with optimization
  • Analyses can be prepared

This makes EmiCo. lite a tool for more efficient processes, lower costs and regulatory security.

EmiCo. lite is calibrated at the factory and ready for use in less than two hours. Installation takes place directly at the desired pool - all that is required is a power connection.
A clearly structured installation package with documentation and configuration instructions supports every step. Thanks to this plug & play architecture, neither lengthy training courses nor external specialists are required.

EmiCo. lite is designed for minimal maintenance:

  • Integrated zero gas cylinder for automatic daily calibration with nitrogen
  • Halbjährliche Kalibrierung in <15 Minuten – mit vorkonfektionierten Kalibriergasbeuteln, die einfach angeschlossen werden
  • No contact with waste water

EmiCo. lite thus considerably reduces the effort involved and ensures permanently precise results.

The recorded data is transferred directly to the EmiCo. Cloud. Thanks to the integrated eSIM, it can be accessed in real time from any location. This allows operators to maintain an overview of their processes at all times - securely and across all locations.

With the optional EmiCo. Gateway, the data can also be integrated bidirectionally into the wastewater treatment plant's control system. All connections are encrypted and compliant with EU-NIS2 and applicable KRITIS requirements.

EmiCo. lite - Emission measurement for wastewater treatment plants

You will find all the important facts, background and further information in our brochure.

Your advantages with EmiCo. lite

  • Quick entry into emission monitoring - plug & play in two hours
  • Real-time measurement of N₂O, CH₄, CO₂, O₂ - regulatory relevant
  • Two measuring points with cloud dashboard - real-time overview, quick intervention possible
  • Bi-annual calibration within minutes - with material sent to you, simple and reliable
  • AI-supported software - recommendations for increasing efficiency and sustainability

Scientifically based & in practical use

EmiCo. lite is already being used by numerous operators - including in Stuttgart, Reutlingen, Trier, Bietigheim-Bissingen, Heilbronn, Aarhus, Lolland, Lyngby, Schwäbisch Hall and Friedrichshafen. Certifications and innovation awards confirm the scientific basis and innovative strength of the system.

Next steps - your path to a climate-neutral wastewater treatment plant

EmiCo. lite is a quick and cost-effective way to get started with emissions monitoring. Operators not only meet legal requirements, but also create the basis for a climate-friendly future.

Contact us

Variolytics enables the real-time measurement of nitrous oxide, making critical processes visible. Talk to our experts.